Error Code E Sd
Sub PCB Communication Error — Main MICOM and Sub MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check all loose connections between Main PCB and Sub PCB. Reconnect any loose connectors.
- 2
Measure voltage at Sub CON1 pins 8–33. Expected: not 0 or 5 V. If 0 or 5 V, check Sub PCB connection (possible loose connector) and replace Sub PCB if connection is secure.
- 3
Measure voltage at Sub CON1 pins 10–33. Expected: not 0 or 5 V. If 0 or 5 V, check Sub PCB connection and replace Sub PCB if needed.
- 4
Measure voltage at Main CON3 pins 1–15. Expected: not 0 or 5 V. If 0 or 5 V, check Display PCB connection (loose connector) and replace Display PCB if connection is secure.
- 5
Measure voltage at Main CON3 pins 3–15. Expected: not 0 or 5 V. If 0 or 5 V, check Display PCB connection and replace Display PCB if needed.
- 6
If all voltages are correct, explain normal operation to customer.
This Error Applies To
LG LF29H8330 Series Refrigerators